PreviewNameParameterApplicationSummary
QS-Monitor AMI InspectorConductivity
Hydrogen
Oxygen
pH
Resistivity
Cooling Water
Feedwater, Steam and Condensate
High Purity Water
Pharmaceutical Water
Pool & Sanitary
Potable Water
Wastewater
Portable quality assurance (verification) of existing on-line measurements. Available for conductivity, resistivity, hydrogen, oxygen and pH measurements. Conductivity 0 - 100 mS Hydrogen 0 - 800 ppb 0 - 50% Saturation Dissolved Oxygen 0.01 ppb - 20 ppm 0 - 200 % Saturation pH Range 1 - 12 pH Resistivity 0.01 - 18.18 MΩ-cm
Handheld Chematest 30/35Chlorine
Chlorine Dioxide
Conductivity
Cyanuric Acid
Disinfectants
Ozone
pH
Redox Potential
Potable WaterPortable kit for disinfectants, cyanuric acid, pH and redox potential measurements. Dust and water protected (IP67), removable cuvette adapter. Chlorine (free, total, combined) 0 - 10 ppm Chlorine Dioxide 0 - 19 ppm Ozone 0 - 4 ppm pH Range (with phenol red) 6.5 - 8 pH Cyanuric Acid 0 - 100 ppm via sensor connections (Chematest 35 only): pH Range 1 - 13 ph Redox Potential (ORP) -400 - +1200 mV Conductivity 0 - 100 mS

 

AMI Turbiwell w/LEDTurbidityPotable WaterContact-free turbidity measurement; approved alternative method to US EPA 180.1 / ISO 7027

Turbidity 0 - 200 NTU

AMI Turbiwell PowerTurbidityFeedwater, Steam and CondensateContact-free turbidity measurement for corrosion product trend monitoring

Turbidity ISO 0 - 200 NTU

Turbidity EPA W/LED 0-100 NTU
AMI Turbiwell 7027TurbidityCooling Water
Pool & Sanitary
Potable Water
Wastewater
High precision, non-contact nephelometer based on ISO 7027 (EN 27027, DIN 38404) for the continuous measurement of turbidity in pure water, potable water, surface water treatment and effluent.

Turbidity 0 - 200 NTU

AMI TurbitraceTurbidityHigh Purity Water

Automatic and continuous measurement of low level turbidity in pure and ultra pure water (ISO/DIN standard)

Turbidity 0.000 - 100 NTU/FNU

AMI TurbitrackTurbidityPool & Sanitary
Potable Water

ISO 7027 compliant determination of turbidity under process pressure conditions

Turbidity 0 - 100 NTU/FNU

AMI LineTOCTOCHigh Purity Water
Pharmaceutical Water

Online monitoring for Total Organic Carbon according to USP <643> EP 2.2.44

Total Organic Carbon (TOC) 0 - 1000 ppb

AMI Sodium ASodiumFeedwater, Steam and Condensate
High Purity Water

Analyzer for the continuous determination of dissolved sodium for samples with pH ≥2

Sodium 0.1 ppb - 10 ppm

AMI Sodium PSodiumFeedwater, Steam and Condensate
High Purity Water

Analyzer for the continuous determination of dissolved sodium for samples with pH ≥7

Sodium 0.1 ppb - 10 ppm

AMI SoditraceSodiumFeedwater, Steam and Condensate
High Purity Water

Automatic measurement for trace amounts of dissolved sodium ions in high purity water applications and steam generation

Sodium 0.001 ppb - 10 ppm

AMI Silitrace UltraSilicaHigh Purity Water

Complete monitoring system for the automatic, continuous measurement of trace amounts of silica in ultra pure water.

Silica 5 ppt (0.005 ppb) - 25 ppb

AMI SilitraceSilicaFeedwater, Steam and Condensate

Automatic determination for trace concentrations of silica in water steam cycles

Silica 0 - 1000 ppb

AMI SilicaSilicaFeedwater, Steam and Condensate

Complete monitoring system for the automatic, continuous measurement of silica in water steam cycles

Silica 1 - 5000 ppb

AMI Phosphate-IIPhosphateCooling Water
Potable Water
Wastewater

Colorimetric process analyzer for the automatic, continuous measurement of phosphate.

Phosphate (PO4) 0.01 - 10 ppm

AMI Phosphate HLPhosphateCooling Water
Feedwater, Steam and Condensate

Complete monitoring system for the automatic, continuous measurement of phosphate in boiler water

Phosphate (PO4) 0 - 50 ppm

Phosphate (P-PO4) 0 - 16 ppm

AMI pH:mV/pH:mV PoolpH
pH and Redox (simultaneous)
Redox (ORP)
Pool & Sanitary

Monitor for simultaneous, continuous measurement of pH and redox (ORP) potential in pool water.

pH Range 1 - 13 pH

Redox Potential (ORP) -400 - +1200 mV

AMI pH:mV/pH:mV M-FlowpH
pH and Redox (simultaneous)
Redox (ORP)
Cooling Water
Potable Water
Wastewater

Dual channel monitor for simultaneous, continuous measurement of pH and Redox (ORP) potential in potable water and effluents.

pH Range 1 - 13 pH

Redox Potential (ORP) -400 - +1200 mV

AMI pH/Redox; QV-FlowpH
Redox (ORP)
Cooling Water
Feedwater, Steam and Condensate
High Purity Water

Long term stable potentiometric determination of pH value or redox potential

pH Range 1 - 12 pH

Redox Potential (ORP) -500 - +1500 mV

AMI pH/Redox; M-FlowpH
Redox (ORP)
Potable Water
Wastewater

Potentiometric measurement of pH value and/or redox potential (single or dual channel)

pH Range 1 - 13 pH

Redox Potential (ORP) -400 - +1200 mV

AMI Oxytrace QEDOxygenFeedwater, Steam and Condensate
High Purity Water

Measurement of dissolved oxygen in high purity water including integrated auto-verification

Dissolved Oxygen 0 ppb - 20 ppm

Saturation 0 - 200 %

AMI OxytraceOxygenCooling Water
Feedwater, Steam and Condensate
High Purity Water

Continuous amperometric measurement of trace dissolved oxygen concentrations in high purity water

Dissolved Oxygen 0 - 20 ppm

Saturation 0 - 200 %

AMI OxysafeOxygenCooling Water
Pool & Sanitary
Potable Water

Amperometric measurement of dissolved oxygen

Dissolved Hydrogen (H2) 0 - 800 ppm

Saturation 0 - 50 %

AMI SAC 254DOC
Organics
SAC254
TOC
UV Absorption
Potable Water
Wastewater

Measurement of UV absorption at 254nm (SAC254) for monitoring of organic contamination

UV Absorption 0-5 ppm

UV Transmission 0-5 ppm

DOC, TOC 0-6 ppm

AMI Hydrogen QEDHydrogenFeedwater, Steam and Condensate

Continuous measurement of dissolved hydrogen for corrosion monitoring in water steam cycles

Dissolved Hydrogen (H2) 0 - 800 ppm

Saturation 0 - 50 %

AMI HydrazineCarbohydrazide
Hydrazine
Feedwater, Steam and Condensate

Membrane-free, amperometric three electrode system for determination of hydrazine or carbohydrazide

Hydrazine 0-600 ppm

Carbohydrazide 0-600 ppm

AMI Codes-II TCDichloramine
Disinfectants
Total Chlorine
Cooling Water
Pool & Sanitary
Potable Water
Wastewater

Automatic, continuous measurement of total chlorine in potable water, sanitary water, cooling water and effluent.

Total Chlorine 0 - 5 ppm

Dichloramine by calculation

 
AMI Codes-II O3Disinfectants
Ozone
Pharmaceutical Water

Photometric ozone measurement per DIN 38408-3

Ozone 0 - 500 ppm

AMI Codes-IIChlorine
Chlorine Dioxide
Disinfectants
Ozone
Cooling Water
Pool & Sanitary
Potable Water
Wastewater

Photometric measurement and control system for disinfectant concentrations

Free Chlorine 0-5 ppm

Chlorine Dioxide 0-6 ppm

Ozone 0-2 ppm

AMI Codes-II CCBound Chlorine
Chlorine
Disinfectants
Free Chlorine
Total Chlorine
Cooling Water
Pool & Sanitary
Potable Water
Wastewater

Differentiated photometric determination of chlorine according to AWWA 4500-Cl G / EN ISO 7393-2

Free Chlorine 0-5 ppm

Bound Chlorine 0-5 ppm

Total Chlorine 0-6 ppm

AMI Solicon 4Conductivity
Salinity
Specific Conductivity
TDS
Cooling Water
Pool & Sanitary
Potable Water

Measuring of specific conductivity, TDS or salinity

Specific Conductivity 0.1 uS/cm - 100 mS/cm

Salinity (as NaCl) 0 - 4 %

TDS (Coefficient) 0 - 20 g/l

AMI ResconConductivity
Resistivity
Specific Conductivity
High Purity Water

Complete monitoring system for the automatic, continuous measurement of the specific resistivity / specific conductivity in high purity water.

Resistivity 0.01 - 18.18 MΩ

Specific Conductivity 0.055 - 1000 uS/cm

AMI Powercon AcidConductivity
Conductivity after Cation Exchange (CACE)
Feedwater, Steam and Condensate

Automatic, continuous measurement of CACE (conductivity after cation exchange).

Acid Conductivity 0.055 - 1000 uS/cm

AMI Powercon SpecificConductivity
Specific Conductivity
Feedwater, Steam and Condensate

Automatic, continuous measurement of specific (total) conductivity.

Specific Conductivity 0.055 - 1000 uS/cm

AMI Deltacon DGConductivity
Conductivity after Cation Exchange (CACE)
pH
Specific Conductivity
Feedwater, Steam and Condensate

Complete monitor for specific conductivity, CACE and degassed CACE according to ASTM D4519-94 via sample reboiler.

Conductivity (specific, acid, degassed acid) 0.055 - 1000 uS/cm

pH Range 7.5 - 11.5

Alkalizing Agent Concentration in ppm

AMI Deltacon PowerConductivity
Conductivity after Cation Exchange (CACE)
pH
Specific Conductivity
Feedwater, Steam and Condensate

Monitor for conductivity before and after cation exchange (CACE) with conventional resin columns.

Specific Conductivity 0.055 - 1000 uS/cm

Acid Specific Conductivity 0.055 - 1000 uS/cm

pH Range 7.5 - 11

Alkalizing Agent Concentration in ppm

AMI TridesBromine
Chlorine
Chlorine Dioxide
Disinfectants
Free Chlorine
Iodine
Cooling Water
Pool & Sanitary
Potable Water
Wastewater

Amperometric measurement and control system for disinfectant concentrations

Free Chlorine 0-5 ppm Chlorine Dioxide 0-3 ppm Ozone 0-1 ppm
AMI CACEConductivity
Conductivity after Cation Exchange (CACE)
Specific Conductivity
Feedwater, Steam and Condensate

Conductivity before and after cation exchange (CACE) with an EDI module for continuous, automatic resin regeneration.

Specific Conductivity 0.055-1000 μS/cm Acid Conductivity 0.055-1000 μS/cm pH Range 7.5-11.5 Alkalizing agent Concentration in ppm
AMI ISE UniversalAmmonium
Fluoride
Potable WaterUniversal AMI Monitor for ammonium, nitrate and fluoride.
Filter: Reset