Industrial Water and Green Hydrogen

Home / Industries / Online Power and Steam Monitoring


Reliable Online Monitoring for Industrial Water

Precise water quality monitoring is essential for industrial processes in manufacturing, energy, and chemical industries. Continuous measurement of key parameters like pH, conductivity, and turbidity ensures process efficiency, reduce operation cost, protects equipment and maintains regulatory compliance.

Our advanced online monitoring solutions provide real-time data, enabling proactive maintenance and sustainable water management. With high accuracy and low maintenance requirements, our instruments support reliable operations and long-term cost savings.

Reliable Online Monitoring for Water in Hydrogen Production

High-purity water is essential for hydrogen production, especially in electrolyzers, where impurities can reduce efficiency and lifespan significantly. Continuous monitoring of key parameters like conductivity, total organic carbon (TOC), and silica ensures optimal performance and protects critical equipment.

Swan’s advanced online monitoring solutions provide real-time data, enabling precise control over water quality. With high accuracy and low maintenance requirements, these instruments support efficient hydrogen production, ensuring compliance with industry standards and long-term operational reliability.

Typical Instrumentation in the Industrial Water and Hydrogen Production

Choose your application

Industrial
Raw Water Intake Demineralized Water Treatment Plant Demineralized Plant Outlet Process Water Treatment Plant Make-up Water Condensate Condensate Polisher Outlet Feedwater Boiler Water Steam Cooling Water Return Condensate from Industrial Applications Effluents / Wastewater ReUse Water Treatment

Raw Water Intake

Key Parameter

  • pH
  • Specific Conductivity
  • UV254 (Organics Trend)
  • Turbidity
  • Disinfectant

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

Demineralized Water Treatment Plant

Key Parameter

  • pH
  • Specifiv Conductivity
  • Sodium
  • Silica
  • Total Organic Carbon
  • UV254 (Organics Trend)
  • Turbidity
  • Disinfectant

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

Demineralized Plant Outlet

Key Parameter

  • Specific Conductivity
  • Total Organic Carbon
  • Silica
  • Sodium

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

Process Water Treatment Plant

Key Parameter

  • pH
  • Specific Conductivity
  • UV254 (Organics Trend)
  • Turbidity
  • Disinfectant

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

Make-up Water

Key Parameter

  • Specific Conductivity
  • Silica
  • Sodium

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

Condensate

Key Parameter

  • pH
  • Conductivity After Cation Exchange
  • Sodium
  • Dissolved Oxygen
  • Specific Conductivity
  • Degassed Conductivity After Cation Exchange
  • Turbidity

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

Condensate Polisher Outlet

Key Parameter

  • Conductivity After Cation Exchange
  • Sodium
  • Specific Conductivity
  • Silica

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

Feedwater

Key Parameter

  • pH
  • Specific Conductivity
  • Conductivity After Cation Exchange
  • Dissolved Oxygen
  • Dissolved Hydrogen
  • Oxidation/Reduction Potential
  • Turbidity

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

Boiler Water

Key Parameter

  • pH
  • Specific Conductivity
  • Conductivity After Cation Exchange
  • Sodium
  • Silica
  • Phosphate
  • Turbidity

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

Steam

Key Parameter

  • pH
  • Conductivity After Cation Exchange
  • Sodium
  • Degassed Conductivity After Cation Exchange
  • Dissolved Hydrogen
  • Silica

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

Cooling Water

Key Parameter

  • pH
  • Specific Conductivity
  • Disinfectant
  • Phosphate
  • Turbidity
  • Oxidation/Reduction Potential

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

Return Condensate from Industrial Applications

Key Parameter

  • pH Value
  • Conductivity After Cation Exchange
  • Specific Conductivity
  • Degassed Conductivity After Cation Exchange
  • Sodium
  • Silica
  • Dissolved Oxygen
  • Turbidity

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

Effluents / Wastewater

Key Parameter

  • pH
  • Specific Conductivity
  • Turbidity
  • Dissolved Oxygen

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

ReUse Water Treatment

Key Parameter

  • pH
  • Specific Conductivity
  • UV254 Organics Trend
  • Turbidity
  • Disinfectant

Optional parameters depending on water quality, water treatment process, power plant configuration,
operation mode, metallurgy and chemical treatment applied

Green Hydrogen PEM-Electrolyzer
Process Water (Feedwater) Pure Water Loop Pure Water Loop After Polisher Cooling Water

Process Water (Feedwater)

Key Parameters

  • Conductivity
  • Total Organic Carbon
  • Silica

Pure Water Loop

Key Parameters

  • Conductivity
  • pH

Pure Water Loop After Polisher

Key Parameters

  • Conductivity
  • Total Organic Carbon

Cooling Water

Key Parameters

  • Conductivity
  • pH/Redox
  • Disinfection

Green Hydrogen Alkaline Electrolyzers
Process Water (Feedwater) Alkaline Water Loop Alkaline Water Loop After Lye Tank

Process Water (Feedwater)

Key Parameters

  • Conductivity
  • Total Organic Carbon
  • Silica

Alkaline Water Loop

Key Parameters

  • Conductivity
  • pH

Alkaline Water Loop After Lye Tank

Key Parameters

  • Concentration

Industrial Water and Green Hydrogen Downloads

Product Overview

Reliable Online Monitoring of Industrial Water Brochure

Our complete product overview, sorted by parameter with all essential information collected in one document.

DOWNLOAD
Water Steam Introduction for Non-Chemists

Product Overview

Reliable Online Monitoring for Water in the Hydrogen Production Brochure

Our complete product overview, sorted by parameter with all essential information collected in one document.

DOWNLOAD

Get in Contact

Would you like more information on Swan water steam monitoring equipment or do you need support of our water steam monitoring experts? Just leave us a message below.